Purpose:
Designed for grouting, anchoring and supporting in applications that require a short turnaround time. Ideal for cold weather placement. It is non-shrink, non-metallic and contains no added chlorides.
Packaging:
50 lb pail
Consistency:
Plastic to fluid
Uses:
FS Grout is ideal for a wide variety of applications that require a short turnaround time.
- Precision Grouting: Machinery bases, compressors, punch presses, generators
- Structural Grouting: Steel columns, precast columns, crane rails, beams
- Anchoring: Guard rails, sign posts, dowels, rods, bolts
Downloads
Tech Sheet
SDS
How much do I need?
(0.43) Grouting & Anchoring
Radius:
Length:
You need 0 50lb Bags of Grout for your 0 cubic foot Cylinder.
Length:
Width:
Depth:
You need 0 50lb Bags
Physical Properties
Compressive Strength (ASTM C109 via C1107)
Set
1 Day
3 Day
7 Day
28 Days
Fluid
3,300 psi
5,500 psi
6,000 psi
8,000 psi
*Note:
Water Ratio = 4.5 qts
Rate of Set (ASTM C266)
Working Time
Initial Set
Final Set
:30
:45
1:00
Product Standards & Approvals
Standards
Section Number
ASTM C1107, Corp of Engineers CRD C621
03 60 00 Grouting