Purpose:
MP Grout is designed to provide high flexural and compressive strength performance from plastic to fluid consistencies. MP Grout is non-metallic, non-shrink, non-corrosive and contains no added chlorides. Hardens free of bleeding, segregation and shrinkage. Excellent flowability.
Packaging:
50 lb bag
Consistency:
Plastic to fluid
Uses:
MP Grout is ideal for a wide variety of precision applications that include:
- Precision Grouting: Machinery bases, compressors, punch presses, generators
- Structural Grouting: Steel columns, precast columns, crane rails, beams
- Underwater Grouting: Form and pump applications
- Anchoring: Guard rails, sign posts, dowels, rods, bolts
- Pumping Applications: Excellent flowability
Downloads
Tech Sheet
SDS
How much do I need?
(0.43) Grouting & Anchoring
Radius:
Length:
You need 0 50lb Bags of Grout for your 0 cubic foot Cylinder.
Length:
Width:
Depth:
You need 0 50lb Bags
Physical Properties
Compressive Strength (ASTM C109 via C1107)
Set
1 Day
3 Day
7 Day
28 Days
Plastic - B
4,800 psi
7,100 psi
8,000 psi
10,000 psi
Flowable - C
4,500 psi
6,600 psi
7,300 psi
9,000 psi
Fluid - D
3,700 psi
5,300 psi
6,400 psi
8,000 psi
*Note:
B = 3.0 qts | C = 4 qts | D = 4.5 qts
Rate of Set (ASTM C266)
Set
Working Time
Initial
Final
Plastic - B
:40
1:09
2:15
Flowable - C
2:00
2:45
4:30
Fluid - D
2:30
3:30
5:30
*Note:
B – 100%-125% flow table (ASTM C230, 5 drops in 3 seconds)
C – 125%-145% flow table (ASTM C230, 5 drops in 3 seconds)
D – 28 second flow cone method (ASTM C939)
Product Standards & Approvals
Standards
Section Number
ASTM C1107, Corp of Engineers CRD C621
03 60 00 Grouting