Purpose:

MP Grout is designed to provide high flexural and compressive strength performance from plastic to fluid consistencies.  MP Grout is non-metallic, non-shrink, non-corrosive and contains no added chlorides.  Hardens free of bleeding, segregation and shrinkage.  Excellent flowability.

Packaging:

50 lb bag

Consistency:

Plastic to fluid

Uses:

MP Grout is ideal for a wide variety of precision applications that include:

  • Precision Grouting:  Machinery bases, compressors, punch presses, generators
  • Structural Grouting:  Steel columns, precast columns, crane rails, beams
  • Underwater Grouting:  Form and pump applications
  • Anchoring:  Guard rails, sign posts, dowels, rods, bolts
  • Pumping Applications:  Excellent flowability

Downloads

Tech Sheet

SDS

How much do I need?

(0.43) Grouting & Anchoring

Radius:

Length:

You need 0 50lb Bags of Grout for your 0 cubic foot Cylinder.

Length:

Width:

Depth:

You need 0 50lb Bags

Physical Properties

Compressive Strength (ASTM C109 via C1107)

Set
1 Day
3 Day
7 Day
28 Days
Plastic - B
4,800 psi
7,100 psi
8,000 psi
10,000 psi
Flowable - C
4,500 psi
6,600 psi
7,300 psi
9,000 psi
Fluid - D
3,700 psi
5,300 psi
6,400 psi
8,000 psi

*Note:
B = 3.0 qts | C = 4 qts | D = 4.5 qts
Rate of Set (ASTM C266)

Set
Working Time
Initial
Final
Plastic - B
:40
1:09
2:15
Flowable - C
2:00
2:45
4:30
Fluid - D
2:30
3:30
5:30

*Note:
B – 100%-125% flow table (ASTM C230, 5 drops in 3 seconds)
C – 125%-145% flow table (ASTM C230, 5 drops in 3 seconds)
D – 28 second flow cone method (ASTM C939)

Product Standards & Approvals

Standards
Section Number
ASTM C1107, Corp of Engineers CRD C621
03 60 00 Grouting